Re: Abysmal Upload Speed in ESXi 5.1

$
0
0

RE kozzy30320111…

 

Your issue could be a non-enabled / not present / defective battery for the write cache.

 

I deal just with HP Servers. They have the SmartArray P212/P410 or new P222/P420 as the default RAID Controllers.

 

When the Battery or Flash Write Cache (BBWC or FBWC) is disabled, defective or not present, I have an upload ratio to the ESXi Datastore of 3 MByte/Sec.

An direct to the on-board SATA Controller attached SATA-HDD over 60MByte/sec.

 

When adding the Battery to the RAID Card - all went fine.

Upload normally over 80MByte/sec on big files to the Datastore wich resides on the RAID Controller.

 

Regards,

 

Josip.